PSG Plus Extruded ATEX 180: controlled ATEX sample line up to 180 °C
The PSG Plus Extruded ATEX 180 is developed for continuous extractive gas analysis in potentially explosive environments that require a holding temperature of up to 180 °C. The line transports the humid sample gas from the sampling point to the analysis room at a constant temperature above the dew point and acid dew point. This prevents condensation of water vapour on the way, gas components are not washed out and the analyser keeps working reliably, even at outdoor temperatures down to -20 °C (solutions down to -52 °C on request).
Application
The PSG Plus Extruded ATEX 180 is suitable for use in Ex zones 1 and 2 in the chemical and petrochemical industries, power plants, the steel industry and other process environments where higher holding temperatures combined with ATEX certification are required. The line offers 30 °C more holding temperature than the ATEX 150-variant, which may be necessary for gas streams with a higher acid dew point.
Technology
The line has a thick-walled extruded outer jacket of TPU or PVC, flame-retardant and extremely weather-resistant. Heating is provided by a high-grade Ex heating cable of 60 W/m with a maximum cable temperature of 250 °C. Isolatie is uitgevoerd met glasvezel- of thermisch vlies. Inner tubes of PTFE, PFA, stainless steel or special alloy are available, optionally replaceable. The electrical connection is via a M25-kabeluitgang to an ATEX junction box.
Functions and options
Temperature control up to a maximum of 180 °C is via an external temperature controller with limiter via the integrated PT100-sensor (e.g. FRBL1 with SSR or NGC-20-CL-E). The line is available up to 300 metres on a cable reel and can be cut every metre on site without loss of function. Ready-made lengths ex works are also possible.
Properties
- Certified for use in Ex zones 1 and 2
- Temperature controller with limiter required
- Ex heating cable 60 W/m, max. cable temperature 250 °C
- Max. holding temperature 180 °C at -20 °C ambient
- Available up to 300 metres on a cable reel
- Heating circuit up to 50 metres
- Can be cut every metre on site or ready-made ex works
- Thick-walled extruded outer jacket: TPU or PVC (flame-retardant, weather-resistant)
- Outer diameter: 40 mm (1x6 mm inner tube), 43 mm (2x6 mm), 45 mm (2x8 mm)
- Inner tube of PTFE, PFA, stainless steel or special alloy
- Degree of protection IP64
- Ambient temperature: -20 to +65 °C
- Up to 12 inner tubes as an option
- Replaceable inner tubes as an option
- Power supply: 230 V AC
ATEX certification of heating cable
| Feature | Value |
|---|
| Ex class | III 2G Ex 60079-30-1 IIC T6 to T2 Gb |
| Ex class dust | II 2D EX 60079-30-1 IIIC Txxx°C Db |
| Temperature class | T6 to T2 (depending on version) |
| Max. cable temperature | 250 °C |
Technical specifications
| Feature | Value |
|---|
| Max. holding temperature | 180 °C |
| Heating cable type | Ex cable 60 W/m |
| Power | 60 W/m |
| Max. heating circuit | 50 m |
| Insulation thickness | 10 mm |
| Outer jacket | TPU or PVC extruded |
| Max. operating pressure PTFE DN4/6 | 5,8 bar at 150 °C |
| Max. operating pressure RVS316L | 400 bar |
| Degree of protection | IP64 |
| Ambient temperature | -20 to +65 °C |